Registered
with the Environment
Agency
Click pictures to
enlarge
Home Page
Fuel Tanks
Bunded & Fuel Stations
IBCs and Baffled Tanks
Recycled Containers
New Barrels and Drums
New Water Tanks
Biofuel Tanks &
Drums
Rain Savers/
Water Butts
Fittings
FAQs & Links
Company
Information
Place an Order
Contact Us
What's New
New Barrels are
popular for a
Canoe Safe, multi-purpose Storage Bin,
Feed Bin, Raft building float etc
Car valeting companies go to IBC page for
Baffled Tanks.
Conical Tanks
-
Black IBC Tanks
-
New and Recycled Bio Fuel Units
-
New
Waste Oil Banks
-
Self-Build Customers
phone for septic tank choices, including sewage treatment plant and underground
water tanks
Most items in stock
Phone
01594 833308
Fire protection tanks
Biodiesel
Bunded Tanks
See new Drum Bund Containers on New Barrels and Drum page
Registered
Waste Carrier
Capacities and sizes are
approximate.
Prices are plus VAT unless stated otherwise
| |
Bunded Tanks & Fuel Stations
|
Bunded Plastic Fuel Tanks here, Fuel
Stations - Roll Top Derv Stations are below - Steel
Waste Oil Banks too and Biodiesel Storage Tanks + Fireblockers.
|
|
COMMERCIAL AND PRIVATE PREMISES INFORMATION
The Control of Pollution (Oil Storage) (England) Regulations 2001 came into
force on 1st March 2002. Our New Plastic Bunded Tanks
comply with these regulations - so you can buy with confidence. The
standards apply to
all industrial and commercial premises
such as factories and hotels, and institutions like schools and
hospitals.
Impact of legislations on businesses and institutions -It covers above ground storage of oil, where over 200 litres / 44 gallons
are stored.
Since September 2002 it has been a requirement that a tank with a
bund must be used for all new
installations.
A bund must be used from September 2003 for any existing
tanks at significant risk i.e. those that are sited 10 metres from any inland freshwaters or coastal waters or 50 metres
from a well or borehole.
Any existing installation prior to September 2001 must now do a risk assent
and if there is a significant risk it must be bunded. If there is not a
significant risk the tank must in any case be bunded by September 2005.
A bund must be used from September 2005 for all
existing oil storage.
Below we have reproduced information on these regulations as
provided by OFTEC - please see bottom of the page for more details.
All our bunded tanks comply with the legislation and carry a manufacturer's guarantee. You are welcome to send for our free handout on this new
legislation.
We can offer a cost effective way of complying with these
regulations by sourcing our Bunded Tanks from more than one UK manufacturer
to give you the kind of choice that some suppliers are unable to offer.
Each Tank carries a manufacturer's guarantee and they conform to OFTEC standards.
Finally, many come with gauges, including electronic as standard.
OFCERT LICENCE is an Oil Industry Technical Certification
All our Fuel Tanks are made by OFTEC Registered Manufacturers.
|
|
|
|
New Bunded Tank Range
|
|
Tank No. |
Capacity
Litres/Gallons
|
Height
metres - feet |
Width
metres - feet |
Length
metres - feet
|
Tank Style
|
|
DR1000B
Slimline
|
1000 / 220
|
1.35 - 4'5"
|
0.64 - 2'1"
|
1.89 - 6'2"
|

|
|
DR1220B
Slimline
|
1220 / 268 |
1.55 - 5'1"
|
0.9 - 3' 1" |
2.24 - 7'4"
|
 |
|
DV1340B
Vertical
|
1340 / 295
|
1.5 - 4'11"
|
1.41 - 4' 7" |
. |
 |
|
DV2455B
Vertical
|
2455 / 540
|
1.81 - 5' 11
|
1.7 - 5' 7"
|
. |
|
|
DH1235B
Horizontal
|
1235 / 272 |
1.26 - 4' 1"
|
1.28 - 4' 2"
|
1.97 - 6' 5"
|
|
|
DH2500B
Horizontal
|
2500 / 550
|
1.62 - 5' 4"
|
1.45 - 4' 9"
|
2.64 - 8' 8"
|
|
|
DV5000B
Vertical
|
5000 / 1100 |
2.3 - 7' 7"
|
2.12 - 7'
|
. |
. |
|
|
|
Complete Fuel Stations
Do you need an answer to your
vehicle fuel storage?
For a comprehensive
solution to you oil storage requirements we have sourced three separate
configurations for you to choose from.
1235 litres/ 272 gallons or 2500 litres /550 gallons
with Delivery Unit incorporated - everything you need to store fuel.
D1235FS 1235 litre / 272 gallon = Length 1.90m - 6ft 3" Width
1.25m -
4ft 1" Height 1.60m - 5ft 3"
D2500FS 2500 litre / 550 gallon = Length 2.64m - 8ft 8" Width 1.45m -
4ft
9" Height 1.77m - 5ft 10"
D5000FS - 5000 litre / 1100 gallon = Length 2.68m -
8ft 9" Width 2.12m - 6ft 11" Height 2.44m - 8ft
|
|
Setup 1 -
Complete Fuel Stations
1235 litres / 272 gallons
and
2500 litres / 550 gallons |
_small.JPG)
|
_small1.JPG) |
 |
 |
 |
|
Ring 01594 833308
to buy from stock |
_small.JPG) |
Auto-shut off nozzle |
Includes
Hose and Nozzle
Contents Gauge |
Precision Metering |
_small.JPG) |
|
5000 litre / 1100 gallons |
_small.JPG)
|
_small.JPG) |
_small.jpg) |
_small.jpg) |
_small.JPG) |
|
|
|
Setup 2 - Complete Fuel Centres - not available at the moment.
|
|
|
|
Setup 3 -
Premier Range
5,000 litres / 1100 gallons
and
7,500 litres / 1650 gallons
and
10,000 litres / 2200 gallons
|

|
|
Tank features state-of-the-art pollution control and electronic
filling/monitoring equipment. |
Integral protection from leakage and overfilling.
|

|
|
Delivery of these Fuel Stations is
free to most postcode areas
2,500 and 3,500 now available too - both Horizontal
Ask for
B2500SF or B3500SF |
B5000SF
5,000 litre
Length: 2.525m
Width: 2.365m
Height: 2.890m |
B7500SF
7,500 litre
Length: 2.845m
Width: 2.685m
Height: 3.04m |
Comes with
Watchman Plus &
Full Stop.
240v pump with nozzle and holder.
4 metre hose
2"BSP connection
Non return valve on fill point
|
Lockable hinged cover on top of tank allows easy access to inner tank. |
B10000SF
10,000 litre
Length: 3.05m
Width: 2.89m
Height: 3.180m |
|
For Single Skinned Fuel Tanks
click here.
We can offer a complete changeover service by an OFTEC
Registered Engineer.
All tanks must be installed in accordance with
prevailing legislation and OFTEC guidelines. The total base are of each
tank must be fully supported - if in doubt
contact OFTEC, your local environment
agency or give us a ring. Don't forget to check the manufacturer's warranty
and register your tank.
|
|
|
|
Steel Derv Stations
|
|
_small1.JPG)
|
Ask for a leaflet on our Vandal Resistant Steel Derv Stations - pictured here
with roll shutter.
One of the best tanks on the market for quality and
value.
Just ring 01594 833308 |
|
Just connect up to an electrical supply and you're ready to go
Manufactured to BS799 Standard
Lockable roller shutter door with large security cabinet, the base of
which is tanked with flowforge grating to stop the hose getting covered in
oil.
Channels are fully welded to base so air can circulate underneath - to prevent
corrosion
Tank and bund stiffened internally
Our manufacturer allows enough space between the tank and the bund to
allow for stiffeners to be fitted. Without these in the event of an
overfill the bund may bulge or if the bund is pressurised may burst.
These Roll Top Derv Stations bunds are stiffened and pressure tested to
stand the fluid.
It is manufactured using the same standards for stiffening as the
storage tank (BS799 part 5).
Outside of tank and inside of tank coated with fluid to leave an oily
film to prevent corrosion.
It is fully fabricated, tested then outside of the tank and the
inside of the bund is coated with a wax oil anti-corrosion fluid, then
placed in the bund and sealed around the top. The bund is then
tested.
Easy to install with no underground pipework
Pumping options - 50, 70 and 90 litre per minute pumps available (Price
includes 50 litre per minute pump)
Choice of dispensing options - choice of colours including a corporate
colour - just let us have your BS or RAL reference number.
Complies with all latest Oil Storage Regulations
Pyramid roof for water run off - captive dipsticks for
tank and flask - lifting lugs all included as standard
Completely free-standing without any need for secondary containment.
Plenty of optional extras
Other capacities - 1360 litre, 2700 litre, 3500 litre 4500 litre, 6700 litre,
10,000 litre, 15,000 litre, 20,000 litre and 25,000 litre.
|
Capacity: 430 Litre / 96 Gallons
Length: 1.156m
Base Length 0.98m
Width: 0.842m
Height: 0.860m |
Capacity: 900 Litre / 198 Gallons
Length 1.4m
Width: 1m
Height: 1.2m |
|
|
|
New Steel or Plastic Waste
Oil Banks
Choice of Plastic Waste Oil Banks from stock.
Bespoke steel bunded waste oil tanks, made to your
requirements can be ordered to include lockable cabinets and so on.
|
Bunded Plastic
Waste Oil Tanks |
 |
The vertical Tank shown on the left has a
capacity of
1340 litre / 295 gallons |
Large Sieved Lid.
Tank complies with regulations. |
This Plastic Waste Oil Tank can be
delivered to most postcode areas |
|
|
_small.jpg)
|
_small.jpg) |
_small.jpg) |
_small.jpg) |
_small.jpg) |
_small.jpg) |
| The Tank shown above
has a 1200 litre capacity |
Comes with a lid |
Sieved grill inside lid |
Stock item |
Easy access |
Phone 01594 833308 to buy one |
|
|
|
New Bunded Steel Fuel Tanks and Fuel Banks
Bespoke steel bunded tanks, made to
your requirements can be ordered and include Enclosed Bunded
Tanks, Waste Oil Tanks, Bunded Fuel Stations with Lockable
Cabinets and so
on.
Typical tank
Low level
internal fill and vent points
Hydrostatic contents gauge
Integral protection from leakage and overfilling
Fully compliant with prevailing regulations
240v Pump Kits with automatic shut-off nozzle and flowmeter
110% bunded in accordance with PPG2 Pollution Prevention Guidelines
Additionally strengthened door frame
|
|
The Steel Fuel Station can be fitted
with a variety of electrically operated pumps.
|
 |
 |
_small.JPG) |
_small2.JPG) |
 |
|
12volt dc - 24 volt dc - 110 volt ac and 240volt ac. with a
choice of delivery speeds.
|
Lockable |
Fully integrated |
Range of capacities to order |
See information about this tank in
above section |
**Steel Fuel Station
illustrated with delivery kit fitted.
|
|
|
|
New Bunded Biodiesel Tanks
Suitable for pumping 100%
Biodiesel - warranted.
Comes complete with:
Electronic Watchman Contents Gauge with remote reading, a receiver needs
plugging into mains supply
Flow Meter
Submersible Pump - approximately 45 litres per minute
4 metre Delivery Hose and Automatic Nozzle
Cartridge Filter
2” Fill point, Cap and Chain
Vent
Easy access Flip Lid - this will contain the 2" fill and any appropriate
equipment.
|
|
Fully integrated |
1350 litres - Slimline
HT: 1700mm
W: 900mm
L: 2700mm |
1400 litres - Vertical
Ht: 1800mm
Diameter:
1576mm |
Includes a
submersible pump at approximately 45 litres per minute |
2500 litre - Horizontal
Ht: 1650mm
W:1500mm
L: 2820mm |
With delivery kit fitted. The electronic gauge has a remote
reading for easy monitoring.
|
| |
For private individuals -
The regulations only apply to a private dwelling when the amount stored in a tank
exceeds 3,500
litres / 770 gallons but anything above 2,500 litres on a single family dwelling
needs to be bunded. OFTEC TI/131 and British Standard 5410 Part1 1997 allows up to a maximum of
2,500 litres for a single skin tank, above 2,500 litres it must be bunded.
|
| |
For more information phone 01594 833308. |
For Fittings take a look here
Fittings |
For our New Fuel Tanks click
Fuel Tanks |
For a great range of Water Tanks
Water Tanks |
For our New Bunded
Tanks Bunded Tanks |
|
For Drums, Barrels & small containers
including Cider Barrels - click one of our most hit pages -
New Barrels |
For our 800 and 1000 litre New IBC Tanks
plus Baffled Tanks click
IBCs & Baffled Tanks |
For a variety of shapes and capacities in Water Butts and Rain Savers click
Rain Savers |
In you need cone-shaped conical tanks for your biofuel process click
The Biofuel Tank Page |
For our ever increasing range of fantastic quality Baffled Tanks click
IBC and Baffled Tanks
|
|
Home Page |
For our Recycled
Containers go to Recycled Containers |
Ring before 11.00 for
same day despatch of stock items |
Call into one of our
depots in Gloucestershire |
Open 5 days a week -
come and choose your tank from stock. |
|
FAQs & Links |
What's New |
Place
an Order |
Company Profile
|
Contact Us |
|